A Novel Timing Equation for Predicting Optimal Contrast Medium Enhancement in Abdomen CT Scan Procedure

Authors

  • Muntaser S. Ahmad Department of Medical Imaging, Palestine Ahliya University (Palestine) https://orcid.org/0000-0002-4340-7252
  • Sewar Shibat Radiology, Anatomy, & Neurobiology, Boston University, Boston, USA
  • Wala Bakri Diagnostic Cardiac Sonography, St.Clair College, Windsor, Canada

DOI:

https://doi.org/10.59994/ajamts.2024.1.9

Abstract

Abdominal CT (Computed Tomography) scans are crucial for diagnosing a wide range of abdominal conditions by providing detailed images of the abdominal organs. The aim of this study is to develop and validate a novel timing equation for predicting optimal contrast medium enhancement in abdominal CT procedures. Utilizing a quantitative research design, data was retrospectively collected from 155 patients who underwent CT scans with contrast media, focusing on variables such as age, gender, weight, creatinine levels, and injection parameters. Statistical analysis, including multi-linear regression and ANOVA, was conducted to derive predictive equations for arterial, venous, and delayed times. The results indicated that Location of the cannula significantly influence arterial time, age is significantly influence venous enhancement time, while weight was the only significant predictor of delayed time, demonstrating the need for patient-specific timing in CT scans. In conclusion, the proposed timing equation could enhance diagnostic accuracy and patient care by optimizing contrast enhancement in abdominal CT procedures.

Keywords:

Computed Tomography, Abdominal Examination, Arterial Enhancement, Venous Enhancement, Delay Enchantment

References

A. Oglat et al., “Characterization and Construction of a Robust and Elastic Wall-Less Flow Phantom for High Pressure Flow Rate Using Doppler Ultrasound Applications,” Nat. Eng. Sci., vol. 3, no. 3, pp. 359–377, Oct. 2018, doi: 10.28978/nesciences.468972.

H. Shaheen, A. Alarab, and M. S Ahmad, “Effectiveness of therapeutic ultrasound and kinesio tape in treatment of tennis elbow,” J. Nov. Physiother. Rehabil., vol. 3, no. 1, pp. 025–033, Apr. 2019, doi: 10.29328/journal.jnpr.1001025.

M. S. Ahmad, O. Makhamrah, and M. Hjouj, “Multimodal Imaging of Hepatocellular Carcinoma Using Dynamic Liver Phantom,” in Hepatocellular Carcinoma - Challenges and Opportunities of a Multidisciplinary Approach, vol. 188, no. tourism, IntechOpen, 2022, p. 109632. doi: 10.5772/intechopen.99861.

M. S. Ahmad, N. Suardi, A. Shukri, N. N. Ashikin Nik Ab Razak, O. Makhamrah, and H. Mohammad, “Gelatin-Agar Liver Phantom to Simulate Typical Enhancement Patterns of Hepatocellular Carcinoma for MRI,” Adv. Res. Gastroenterol. Hepatol., vol. 18, no. 05, Jun. 2022, doi: 10.19080/argh.2022.18.555998.

M. S. Ahmad and A. Arab, “Ability of MRI Diagnostic Value to Detect the Evidence of Physiotherapy Outcome Measurements in Dealing with Calf Muscles Tearing,” J. Med. – Clin. Res. Rev., vol. 6, no. 10, pp. 6–11, Oct. 2022, doi: 10.33425/2639-944X.1292.

M. S. Ahmad, B. Rjoub, A. Abuelsamen, and H. Mohammad, “Evaluation of Advanced Medical Imaging Services at Government Hospitals-West Bank,” J. Med. - Clin. Res. Rev., vol. 6, no. 7, pp. 1–7, Jul. 2022, doi: 10.33425/2639-944X.1280.

M. Kmail, M. S. Ahmad, and M. Hjouj, “Evaluating the Accuracy of 128-Section Multi-Detector Computed Tomography (MDCT) in Detecting Coronary Artery Stenosis,” in Proceedings of the 2022 5th International Conference on Digital Medicine and Image Processing, Nov. 2022, pp. 58–62. doi: 10.1145/3576938.3576948.

Muntaser S. Ahmad et al., “Evaluating the efficacy of breast cancer treatments using PET-CT Imaging,” J. Palest. Ahliya Univ. Res. Stud., vol. 2, no. 1, pp. 158–170, May 2023, doi: 10.59994/pau.2023.1.158.

A. A. Oglat, M. Alshipli, M. A. Sayah, O. F. Farhat, M. S. Ahmad, and A. Abuelsamen, “Fabrication and characterization of epoxy resin-added Rhizophora spp . particleboards as phantom materials for computer tomography (CT) applications,” J. Adhes., vol. 98, no. 8, pp. 1097–1114, Jun. 2022, doi: 10.1080/00218464.2021.1878890.

M. Hjouj and M. S. Ahmad, “Reconstruction From Limited-Angle Projections Based on a Transformation,” in Proceedings of the 2022 5th International Conference on Digital Medicine and Image Processing, Nov. 2022, no. 1, pp. 19–23. doi: 10.1145/3576938.3576942.

M. S.Ahmad, S. L. Zeyadeh, R. Odeh, and A. A. Oglat, “Occupational Radiation Dose for Medical Workers at Al-Ahli Hospital in West Bank- Palestine,” J. Nucl. Med. Radiol. Radiat. Ther., vol. 5, no. 1, pp. 1–5, Sep. 2020, doi: 10.24966/NMRR-7419/100017.

O. Makhamrah, M. S. Ahmad, and M. Hjouj, “Evaluation of Liver Phantom for Testing of the Detectability Multimodal for Hepatocellular Carcinoma,” in Proceedings of the 2019 2nd International Conference on Digital Medicine and Image Processing, Nov. 2019, pp. 17–21. doi: 10.1145/3379299.3379307.

M. Ahmad et al., “Chemical characteristics, motivation and strategies in choice of materials used as liver phantom: A literature review,” J. Med. Ultrasound, vol. 28, no. 1, p. 7, 2020, doi: 10.4103/JMU.JMU_4_19.

M. S. Ahmad et al., “A Recent Short Review in Non-Invasive Magnetic Resonance Imaging on Assessment of HCC Stages: MRI Findings and Pathological Diagnosis,” J. Gastroenterol. Hepatol. Res., vol. 9, no. 2, pp. 3113–3123, 2020, doi: 10.17554/j.issn.2224-3992.2020.09.881.

A. A. Oglat, M. Alshipli, M. A. Sayah, and M. S. Ahmad, “Artifacts in Diagnostic Ultrasonography,” J. Vasc. Ultrasound, vol. 44, no. 4, pp. 212–219, Dec. 2020, doi: 10.1177/1544316720923937.

A. Al-Tell, M. Hjouj, M. S.Ahmad, and H. Mohammad, “Justification of Urgent Brain CT Examinations at Medium Size Hospital, Jerusalem,” Atlas J. Biol., pp. 655–660, Dec. 2019, doi: 10.5147/ajb.v0i0.213.

M. S.Ahmad, M. Shareef, M. Wattad, N. Alabdullah, M. D. Abushkadim, and A. A. Oglat, “Evaluation of Exposure Index Values for Conventional Radiology Examinations: Retrospective Study in Governmental Hospitals at West Bank, Palestine,” Atlas J. Biol., pp. 724–729, Dec. 2020, doi: 10.5147/ajb.vi.219.

M. S. Ahmad et al., “Hepatocellular carcinoma liver dynamic phantom for MRI,” Radiat. Phys. Chem., vol. 188, p. 109632, Nov. 2021, doi: 10.1016/j.radphyschem.2021.109632.

S. Hussain et al., “Modern Diagnostic Imaging Technique Applications and Risk Factors in the Medical Field: A Review.,” Biomed Res. Int., vol. 2022, p. 5164970, 2022, doi: 10.1155/2022/5164970.

M. Hjouj, M. S. Ahmad, and F. Hjouj, “Review and improvement of the linear transformation of images,” in AIP Conference Proceedings, 2023, vol. 060003, no. August, p. 060003. doi: 10.1063/5.0165763.

N. Iyad, M. S.Ahmad, S. G. Alkhatib, and M. Hjouj, “Gadolinium contrast agents- challenges and opportunities of a multidisciplinary approach: Literature review,” Eur. J. Radiol. Open, vol. 11, no. June, p. 100503, Dec. 2023, doi: 10.1016/j.ejro.2023.100503.

A. Mouath D, A. Akram, and A. Muntaser S, “Physical activity and health-related quality of life among physiotherapists in Hebron/West Bank,” J. Nov. Physiother. Rehabil., vol. 4, no. 2, pp. 022–027, Jul. 2020, doi: 10.29328/journal.jnpr.1001033.

C. C. Ban et al., “Modern heavyweight concrete shielding: Principles, industrial applications and future challenges; review,” J. Build. Eng., vol. 39, no. March 2022, p. 102290, Jul. 2021, doi: 10.1016/j.jobe.2021.102290.

M. S. Ahmad et al., “Dynamic Hepatocellular Carcinoma Model Within a Liver Phantom for Multimodality Imaging,” Eur. J. Radiol. Open, vol. 7, no. September, p. 100257, 2020, doi: 10.1016/j.ejro.2020.100257.

A. Alarab et al., “Treatment of Lateral Epicondylitis with Physiotherapy during a Clinical Trial: Comparison of Mobilization Technique and Shock Wave,” J. Med. – Clin. Res. Rev., vol. 6, no. 10, pp. 2–6, Oct. 2022, doi: 10.33425/2639-944X.1293.

O. Makhamrah, M. S. Ahmad, D. Doufish, and H. Mohammad, “Internal Auditory Canal (IAC) and Cerebellopontine Angle (CPA): Comparison between T2-weighted SPACE and 3D-CISS sequences at 1.5T,” Radiat. Phys. Chem., vol. 206, p. 110797, May 2023, doi: 10.1016/j.radphyschem.2023.110797.

M. S. Ahmad, O. Makhamrah, and M. Hjouj, “Multimodal Imaging of Hepatocellular Carcinoma Using Dynamic Liver Phantom,” in Hepatocellular Carcinoma - Challenges and Opportunities of a Multidisciplinary Approach, vol. i, no. tourism, IntechOpen, 2022, p. 13. doi: 10.5772/intechopen.99861.

S. A. Muntaser, M. Rumman, R. A. Malash, A. A. Oglat, and S. Nursakinah, “Evaluation of Positioning Errors for in Routine Chest X- Ray At Beit Jala Governmental Hospital,” Inernational J. Chem. Pharamacy Technol., vol. 3, no. 5, pp. 1–8, 2018.

A. Alarab, R. A. Shameh, and H. M. Shaheen, “Shock Wave Therapy and Ultrasound Therapy plus Exercises for Frozen Shoulder Joint Clients,” Adv. Nurs. Patient Care Int. J. Res., vol. 1, no. 2, 2018, [Online]. Available: https://www.researchgate.net/publication/329949756

A. Oglat et al., “Chemical items used for preparing tissue-mimicking material of wall-less flow phantom for doppler ultrasound imaging,” J. Med. Ultrasound, vol. 26, no. 3, p. 123, 2018, doi: 10.4103/JMU.JMU_13_17.

M. Mohammad, M. S.Ahmad, M. Mudalal, A. Bakry, and T. Arzeqat, “The Radioactive Iodine (I-131) Efficiency for the Treatment of Well-Differentiated Thyroid Cancer,” HSOA J. Nucl. Med. Radiol. Radiat. Ther., vol. 5, no. 25, pp. 5–10, 2020, doi: 10.24966/NMRR-7419/100025.

A. Alarab, R. A. Shameh, and M. S. Ahmad, “Muscle contraction exercise for low back pain,” Hong Kong Physiother. J., vol. 43, no. 01, pp. 53–60, Jun. 2023, doi: 10.1142/S1013702523500075.

H. Lusic and M. W. Grinstaff, “X-ray-computed tomography contrast agents.,” Chem. Rev., vol. 113, no. 3, pp. 1641–1666, Mar. 2013, doi: 10.1021/cr200358s.

M. S. Ahmad, O. Makhamrah, N. Suardi, A. Shukri, N. N. A. N. A. Razak, and H. Mohammad, “Agarose and Wax Tissue-Mimicking Phantom for Dynamic Magnetic Resonance Imaging of the Liver,” J. Med. - Clin. Res. Rev., vol. 5, no. 12, Dec. 2021, doi: 10.33425/2639-944X.1250.

M. S. Ahmad et al., “Current Status Regarding Tumour Progression, Surveillance, Diagnosis, Staging, and Treatment Of HCC: A Literature Review,” J. Gastroenterol. Hepatol. Res., vol. 8, no. 2, pp. 2841–2852, 2019, doi: 10.17554/j.issn.2224-3992.2019.07.814.

M. S. Ahmad and H. Mohammad, “Statistical calculation of beta radiotherapy dose using I-131: analysis and simulation method.,” J. Phys. Conf. Ser., vol. 2701, no. 1, p. 012026, Feb. 2024, doi: 10.1088/1742-6596/2701/1/012026.

R. K. Alqam, M. S. Ahmad, and H. Mohammad, “Signal Quantification of Intravenous Contrast Agents Enhancement from Biphase Liver CT Scan Procedures,” J. Phys. Conf. Ser., vol. 2701, no. 1, p. 012064, Feb. 2024, doi: 10.1088/1742-6596/2701/1/012064.

A. Nazzal, M. S. Ahmad, and H. Mohammad, “Justification of Urgent Brain CT scans at Palestinian Government Hospitals,” J. Phys. Conf. Ser., vol. 2701, no. 1, p. 012065, Feb. 2024, doi: 10.1088/1742-6596/2701/1/012065.

M. Rumman, M. S.Ahmad, H. Mohammad, A. A. Oglat, N. Suardi, and H. Altalahmah, “An Assessment of Senior and Junior Medical Imaging Student’s Familiarity With Correct Radiographic Evaluation Criteria and Clinical Training Efficiency,” Int. J. Chem. Pharm. Technol., no. August, 2018.

M. S. Ahmad, A. J. Rizeq, I. A. Abu Saleh, and D. H. Bshara, “Assessing Radiographic Technologist Precision and its Influence on Patient Exposure Index: Analytical Retrospective Study in a Small Palestinian Government Hospital,” J. Palest. Ahliya Univ. Res. Stud., vol. 1, no. 2, pp. 76–85, Dec. 2022, doi: 10.59994/pau.2022.2.76.

M. Shatat and M. S. Ahmad, “The Role of Cardiac MRI and Echocardiography in the Treatment of Cardiac Disorders in the Palestinian Health System,” pp. 130–135, doi: https://doi.org/10.1145/3637684.3637713.

M. K. Henning, T. M. Aaløkken, A. C. Martinsen, and S. Johansen, “The impact of body compositions on contrast medium enhancement in chest CT: a randomised controlled trial.,” BJR open, vol. 5, no. 1, p. 20230054, 2023, doi: 10.1259/bjro.20230054.

A. Adibi and A. Shahbazi, “Automatic bolus tracking versus fixed time-delay technique in biphasic multidetector computed tomography of the abdomen.,” Iran. J. Radiol. a Q. J. Publ. by Iran. Radiol. Soc., vol. 11, no. 1, p. e4617, Jan. 2014, doi: 10.5812/iranjradiol.4617.

Downloads

Published

2024-06-30

How to Cite

S. Ahmad, M. ., Shibat, S. ., & Bakri, W. . (2024). A Novel Timing Equation for Predicting Optimal Contrast Medium Enhancement in Abdomen CT Scan Procedure. Ahliya Journal of Allied Medico-Technology Science, 1(1), 9–14. https://doi.org/10.59994/ajamts.2024.1.9

Issue

Section

Articles